Why is it difficult to switch large-diameter valves? How to solve the problem?

Editor:嘉興美克斯閥門有限公司 │ Release Time:2022-01-12 

Among users who use large-diameter globe valves on a daily basis, they often report a problem that large-diameter globe valves are often difficult to close when they are used in media with a relatively large pressure difference, such as steam, high-pressure water, etc. When closing with force, it is always found that there will be leakage, and it is difficult to close tightly. The reason for this problem is caused by the structural design of the valve and the insufficient output torque of the human limit level.


Analysis of the Difficulty in Switching Large Diameter Valves


The average adult's horizontal limit output force is 60-90kg, depending on different physiques.


Generally, the flow direction of the globe valve is designed to be low in and high out. When a person closes the valve, the human body pushes the handwheel to rotate horizontally, so that the valve flap moves downward to realize the closing. At this time, it is necessary to overcome the combination of three forces, namely :


1) Axial thrust force Fa;


2) Friction force Fb between packing and valve stem;


3) The friction force Fc between the valve stem and the valve disc core


The sum of moments is ∑M=(Fa+Fb+Fc)R


It can be seen that the larger the diameter, the greater the axial thrust force. When it is close to the closed state, the axial thrust force is almost close to the actual pressure of the pipe network (because when it is closed, P1-P2≈P1, P2=0)


For example, a DN200 caliber globe valve is used on a 10bar steam pipe, only the first closing axial thrust Fa=10×πr2=3140kg, and the horizontal circular force required for closing is close to the horizontal circular force that normal human bodies can output. force limit, so it is very difficult for one person to fully close the valve under this condition.


Of course, some factories recommend installing such valves in reverse, which solves the problem of being difficult to close, but there is also the problem that it is difficult to open after closing.


Analysis of the Causes of Internal Leakage of Large Diameter Globe Valves


Large-diameter globe valves are generally used in boiler outlet, main cylinder, steam main and other positions. These positions have the following problems:


1) Generally, the pressure difference at the boiler outlet is relatively large, so the steam flow rate is also larger, and the erosion damage to the sealing surface is also larger. In addition, the combustion efficiency of the boiler cannot be 100%, which will cause the steam at the outlet of the boiler to have a large water content, which will easily cause cavitation and cavitation damage to the valve sealing surface.


2) For the shut-off valve near the boiler outlet and the sub-cylinder, because the steam that has just come out of the boiler has intermittent superheating phenomenon, in the process of its saturation, if the softening treatment of the boiler water is not very good, part of the acid is often precipitated Alkali substances will cause corrosion and erosion to the sealing surface; some crystallizable substances may also adhere to the valve sealing surface and crystallize, resulting in the valve not being able to be tightly sealed.


3) For the inlet and outlet valves of the sub-cylinders, the steam consumption after the valve is large and sometimes small due to production requirements and other reasons. The valve sealing surface causes erosion, cavitation and other damage.


4) Generally, when a large-diameter pipeline is opened, the pipeline needs to be preheated, and the preheating process generally requires a small flow of steam to pass through, so that the pipeline can be heated slowly and evenly to a certain extent before the stop valve can be fully opened to avoid causing the pipeline to rapidly Excessive expansion caused by heating up and damage to some connection parts. However, in this process, the valve opening is often very small, which causes the erosion rate to be far greater than the normal use effect, and seriously reduces the service life of the valve sealing surface.


Solutions to Difficulties in Switching Large Diameter Globe Valves


1) First of all, it is recommended to choose a bellows-sealed globe valve, which avoids the influence of the frictional resistance of the plunger valve and the packing valve, and makes the switch easier.


2) The valve core and seat must be made of materials with good erosion resistance and wear resistance, such as Stellite carbide.


3) It is recommended to adopt a double valve disc structure, which will not cause excessive erosion due to the small opening, which will affect the service life and sealing effect.


主站蜘蛛池模板: 性一交一乱一交A片久久四色 | 久久久久久综合网天天 | 蜜桃色欲AV久久无码精品 | 亚洲乱妇老熟女爽到高潮的片 | 国产啪亚洲国产精品无码亚洲精华国产 | 69堂无码国产精品色四婷婷专区 | 波多野吉不卡中文av | 欧美日本一道道一区二区三 | 在线播放一区二区不卡三区 | 无码av三级毛片完整版 | 精品无码人妻一区 | 麻豆国产第二 | 国产强奷在线播放免费不卡 | 亚洲狼人伊人中文字幕 | 亚州四虎精品久久久 | 好好的曰com久久 | 人妻av久久一区波多野结衣 | 久久国产成人精品国产成人亚洲 | 亚洲午夜精品A片久久W | 欧美日韩精品一区二区免费看 | 性一交一无一伦一精一品 | 无码加勒比一区二区三区 | 国产婷婷理论在线观看 | 2024天天操夜夜操 | 成人a级视频在线观看 | 国产精品美女一区二区视频 | 东京热免费视频一区二区三区 | 男人的天堂在成a | 国产午夜精品一区二区三区软件图片在线电视野花日本大全 | 国产精品久久久久无码人妻 | 国产欧美精品一区二区色综合 | 国产精品麻豆一区二区三区v视界 | 国产一级毛片夜一级毛片 | 久久国产欧美国日产综合抖音 | 欧洲成人4卡5卡6卡7卡 | 中文字幕丝袜一区 | 婷婷丁香久久 | 欧美日韩国产综合在线高清视频 | 99久久九九社区精品 | 伦理片天堂eeuss影院2o12 | 99久久精品这里只有精品 |